Using the PARTS Server
There is a limit to the length of the sequences that can be run through the PARTS algorithm. For details, please click here.
It is possible to input example sequences into both sequence boxes at once by clicking on the link above the "Select Sequence 1 Input" form section.
-
Select a first sequence for analysis.
Selection of a sequence can be done in one of two ways. First, a sequence file in FASTA format can be uploaded using the "Select Sequence File 1" control. Second, raw sequence data can be input in the "Sequence 1" box. Please note that only nucleotides (A, C, G, T, U, or X) should be entered in this box, and lower case nucleotides are forced single stranded. If raw sequence data is specified, a sequence title must be specified with it in the "Sequence Title 1" box. -
Select a second sequence for analysis.
Selection of a sequence can be done in one of two ways. First, a sequence file in FASTA format can be uploaded using the "Select Sequence File 2" control. Second, raw sequence data can be input in the "Sequence 2" box. Please note that only nucleotides (A, C, G, T, U, or X) should be entered in this box, and lower case nucleotides are forced single stranded. If raw sequence data is specified, a sequence title must be specified with it in the "Sequence Title 2" box. -
Select the folding mode.
The PARTS server can be run in three distinct modes: MAP (maximum a posteriori) prediction mode, pairing probability prediction mode, or stochastic sampling mode. By default, the server uses MAP (maximum a posteriori) prediction mode. -
Change default data, if desired.
The PARTS server allows specification of a number of structures, but this is applicable in stochastic sampling mode only. This value has a default, so it is not necessary to specify the value in order to do calculations. -
Add optional data, if desired.
The PARTS server allows specification of a minimum plot bound and maximum plot bound. Neither of these values have defaults filled in, and it is not necessary to specify them in order to do calculations. -
Enter an email address where results can be sent, if desired.
If an email address is specified in the appropriate box, an email will be sent to inform you when calculations are done. Note that failing to enter an email address may cause results to be inaccessible, if you navigate away from the server while calculations are running. -
Begin the calculation.
Press the "Submit Query" button to begin the calculation. If you remain on the server page, the results will appear when they are finished.
For detailed explanations of the PARTS algorithm and its parameters, please click here.