Parameter |
ΔG°37 |
ΔH° |
Symmetrically Equivalent Parameter |
5'AG3' |
–0.55 ± 0.32 |
–3.21 ± 2.76 |
5'UU3' |
5'AU3' |
–1.36 ± 0.24 |
–8.81 ± 2.10 |
5'GU3' |
5'CG3' |
–1.41 ± 0.24 |
–5.61 ± 2.13 |
5'UG3' |
5'CU3' |
–2.11 ± 0.25 |
–12.11 ± 2.22 |
5'GG3' |
5'GG3' |
–1.53 ± 0.27 |
–8.33 ± 2.33 |
5'UC3' |
5'GU3' |
–2.51 ± 0.25 |
–12.59 ± 2.18 |
5'GC3' |
5'GA3' |
–1.27 ± 0.28 |
–12.83 ± 2.44 |
5'UU3' |
5'GG3' |
+0.47 ± 0.96 |
–13.47 ± 8.37 |
5'UU3' |
5'GU3' |
+1.29 ± 0.56 |
–14.59 ± 4.92 |
|
5'GGUC3' |
–4.12 ± 0.54 |
–30.80 ± 8.87 |
5'GGUC3' |
5'UG3' |
–1.00 ± 0.30 |
–6.99 ± 2.64 |
5'UA3' |
5'UG3' |
+0.30 ± 0.48 |
–9.26 ± 4.19 |
|
Per GU end |
+0.45 ± 0.04 |
3.72 ± 0.83 |
|
a: Although the free energy change parameter for GU followed by GU fit to +0.47 kcal/mol, there is a large error and this parameter is set to –0.5 kcal/mol for secondary structure prediction to optimize accuracy.
b: GU followed by UG is generally unfavorable (+0.47 kcal/mol), but is favorable in the one context shown (GC preceding pair and CG following pair). For the favorable case, the single reported parameter (–4.12 kcal/mol) is used for the total of three stacks.